Azure IoT Hub Gen 2
Overview
The Azure IoT Hub Gen 2 integration enables Belden Horizon Data Operations to connect to Azure IoT Hub services via SAS Key or Device Certificate over the MQTT protocol.
Supported communication
- Outbound (Publish data from Edge to Azure IoT Hub) - Yes
- Inbound (Subscribe data from Azure IoT Hub to Edge) - Yes
Configurations
Field | Details | Required |
|---|---|---|
Name | Connector name. | Yes |
Connection Type | Authentication method: SAS Key or Device Certificate. | Yes |
Hostname | DNS name of MQTT host. It can be found in the Overview tab of your Azure IoT Hub. | Yes |
Port | Port of MQTT host. | Yes |
Device ID | ID of the device as shown in your Azure IoT account. | Yes |
Certificate | PEM certificate used to authenticate the device when Connection Type is set to certificate. | No |
Private key | Private key for the device certificate, in PEM format. Must match the Certificate field above. | No |
SAS Key | Primary or secondary shared access key. | Yes |
Integration Topic | Azure IoT Hub MQTT topic for device-to-cloud messages. | Yes |
Throttling limit | Set a limit on the number of outbound messages per second. If sending data to a server that has restrictions on the rate of incoming messages, this ensures that no messages are lost. | No |
Advanced configurations
Field | Details | Required |
|---|---|---|
Parallel Publish Count | Number of messages published in parallel. Higher values increase throughput and resource usage. | No |
Token TTL (minutes) | The token expiry time in minutes. | No |
LWT topic | MQTT topic the broker publishes the Last Will message to if this client disconnects unexpectedly. | No |
LWT payload | Message content published to the LWT topic on unexpected disconnection. Typically a status or alert string. | No |
LWT payload type | Encoding of the LWT payload: string for plain text, base64 for binary data. | No |
LWT QoS | QoS level for the Last Will message: 0 = at most once, 1 = at least once, 2 = exactly once. | No |
LWT retained | When enabled, the broker retains the Last Will message and immediately delivers it to any new subscriber on that topic. | No |
Persistent storage configurations
Field | Details | Required |
|---|---|---|
Persistent storage | If enabled, messages in the outbound queue are stored on disk. If there are interruptions in connection or power loss, messages are retained and eventually sent when the connection is restored. | No |
Persistent storage size limit | Set the size limit for storing persisted data in GB. | No |