title: BHDO 3.11.0
slug: bhdo-v1/bhdo-3110
createdAt: 2023-12-18T18:26:18.936Z
---

Release Date: December 19, 2023

Review the current list of [Limitations](docId\:J4jFH328KdkIZC3MjnpG-).&#x20;

## New Features

| Description                                                                                                                                              |
| -------------------------------------------------------------------------------------------------------------------------------------------------------- |
| **DeviceHub**:<br />Support is now provided for the following drivers:<br />- Siemens S7 CommPlus Symbolic<br />- OSI Agent Advanced<br />- Enron Modbus |

## Enhancements and Improvements

| Description                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               |
| ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| **System**: <br />- The Enable Data Store setting for DeviceHub devices is now saved in template files.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   |
| **DeviceHub**:<br />- New data types are now available for Omron NJ Ethernet (Gen1).<br />- The following options are now available when connecting a device.<br />- **Publish on Polling Interval**<br />- Only available for Gen 2 drivers.<br />- If this option is selected, the driver will always publish messages according to the polling interval configuration. If the driver has not completed the request to read the data at a polling interval, the payload will have a `success=false` message.<br />- If this option is not selected, the driver will not publish a message at the polling interval if the request to read data has not completed.<br />- **Watchdog**<br />- This option is not available for all drivers. For example, drivers that act as servers don't have this option, such as Industrial OT Server and OSI Agent.<br />- If this option is selected, the driver will be monitored based on the Watchdog period (in seconds) you configure. If an issue is detected, then the driver will restart.<br />- The Browse Tags feature is now available for the Beckhoff TwinCAT3 Ethernet(Gen1) driver. |
| **Integration**:<br />- The client email parameter is now available for the Google Pub/Sub connector.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     |
| **Digital Twins**:<br />- The fields for uploading CSV files have been updated.<br />- Models and instances are now saved by new **Save Model** and **Save Instance** buttons.<br />- You can now upload static attributes and dynamic attributes in instance configurations.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                             |
| **Flows Manager**:<br />- The maximum size of logs for flows is now 80 MB, rotated between two log files of 40 MB each.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   |

## Resolved Issues

| Description                                                                                                                                                                                                                                                         |
| ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| **System**: <br />- Fixed issue with backup files with over 25 DeviceHub devices not uploading successfully.                                                                                                                                                        |
| **DeviceHub**:<br />- Fixed issue with the Browse Tags feature returning the incorrect number of tags for the OPC UA Client Advanced driver.<br />- Fixed issue with the Roc800 Ethernet driver crashing after adding a tag with type Opcode180.                    |
| **Analytics**:<br />- Fixed navigation issue while configuring the Tengo script processor.                                                                                                                                                                          |
| **Flows Manager**: <br />- Fixed issue with Flows Managers displaying a `warning` status incorrectly.                                                                                                                                                               |
| **Integration**:<br />- Fixed issue with frequent disconnections from the InfluxDB 2.x TCP connector.<br />- Fixed issue with the Mindsphere connector not being able to send data.<br />- Fixed issue with the log window not resetting when returning to view it. |
| **OPC UA**: <br />- Fixed issue with the OPC UA server showing tags with the bit data type as a string data type.<br />- Fixed issue with importing a hierarchy from DeviceHub from a JSON file and the NodeID Settings are ignored.                                |